Siemens SINUMERIK 840Di Diagnostic Manual page 531

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

11/2006
61273
Channel %1 block %2: Insertion depth too large
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Insertion depth on chamfering too large.
Alarm triggered by following cycles: E_SP_CHA, F_SP_CHA.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Decrease the insertion depth.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61274
Channel %1 block %2: Invalid tool angle
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Invalid tool angle.
Alarm triggered by following cycles: E_SP_CHA, F_SP_CHA.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Check tool angle.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61275
Channel %1 block %2: Target point violates software limit switch!
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Due to a swivel action, the end point is outside the software limit switches.
Alarm triggered by following cycle: E_SP_RP.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Select another retraction plane or approach a suitable interpolation point.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61276
Channel %1 block %2: External tool diameter required for restrictions
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Outer tool diameter required in case of delimitations.
Alarm triggered by following cycle: CYCLE61.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Specify the outer tool diameter.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
Overview of Alarms
NCK alarms
2-531

Hide quick links:

Advertisement

Table of Contents
loading