Overview of Alarms
NCK alarms
15166
Channel %1 user system asup _N_ASUP_SPF not available
Parameters:
%1 = Channel number
Definitions:
By means of the machine data 11610 $MN_ASUP_EDITABLE the function "User-defined system
asup" has been activated. However, the relevant user program could not be found in the specified
search path:
- 1. /_N_CUS_DIR/_N_ASUP_SPF
- 2. /_N_CMA_DIR/_N_ASUP_SPF
The default system asups are used.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Load the user-defined system asup in /_N_CUS_DIR/_N_ASUP_SPF or
/_N_CMA_DIR/_N_ASUP_SPF laden.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
15170
Channel %1 block %2 program %3 could not be compiled
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = String
Definitions:
An error has occurred in compile mode. The (compiler) error message refers to the program specified
here.
Reaction:
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with the Delete key or NC START.
Continuation:
15171
Channel %1 block %2 compiled program %3 older than the relevant
subroutine
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Compiled program file name
Definitions:
When calling a precompiled subroutine, it was noticed that the compiled program is older than the
relevant SPF file. The compiled program was deleted and during start the subroutine is executed
instead of the compiled program.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Perform another precompilation.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
15172
Channel %1 block %2 subroutine %3. No interface available at time of
preprocessing.
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Subroutine name
Definitions:
In compilation mode no program interface of the subroutine to be called was available at the time of
pre-compilation.
Reaction:
Interpreter stop
Interface signals are set.
Alarm display.
Remedy:
Modify parts program or recreate program interfaces and pre-compile programs again.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
2-268
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
11/2006

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents