11/2006
17001
Channel %1 block %2 no memory left for tool/magazine data
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The values of the following tool/magazine data variables in the NC are given by machine data:
- Number of tools + number of grinding data blocks: 18082 MM_NUM_TOOL
- Number of cutting edges: 18100 MM_NUM_CUTTING_EDGES_IN_TOA
Tools, grinding data blocks, cutting edges can be used independently of the tool management.
The memory for the following data is available only if the corresponding bit has been set in 18080
MM_TOOL_MANAGEMENT_MASK.
- Number of monitoring data blocks: 18100 MM_NUM_CUTTING_EDGES_IN_TOA
- Number of magazines: 18084 MM_NUM_MAGAZINE
- Number of magazine locations: 18086 MM_NUM_MAGAZINE_LOCATION
The following variable is determined by software configuration: Number of magazine spacing data
blocks: P2 permits 32 such spacing data blocks.
Definition:
- 'Grinding data blocks': Grinding data can be defined for a tool from type 400 to 499. Such a data
block occupies the additional memory planned for a cutting edge.
- 'Monitoring data blocks': Each cutting edge of a tool can be supplemented by monitoring data.
- If the alarm occurs while writing from one of the parameters $TC_MDP1/$TC_MDP2/$TC_MLSR,
check whether
$MN_MM_NUM_DIST_REL_PER_MAGLOC/$MN_MM_NUM_LOCS_WITH_DISTANCE have been
correctly set.
$MN_MM_NUM_DIST_REL_PER_MAGLOC defines the number of different Index1 statements that
may be made for an Index2 value.
$MN_MM_NUM_LOCS_WITH_DISTANCE defines the number of different buffer storage locations
that may be named in Index2.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department.
- Modify machine data
- Modify the NC program, i.e. reduce the number of items related to the variable which caused the
error condition.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
17010
Channel %1 block %2 no memory left
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
When executing/reading files from the active working memory, it was found that there is not enough
memory space (e.g. for large multidimensional arrays or when creating tool offset memory).
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Make arrays smaller or make more
memory space available for memory management of subroutine calls, tool offsets and user variables
(machine data MM_...).
See /FB/, S7 Memory Configuration
Program
Clear alarm with the RESET key. Restart part program
Continuation:
© Siemens AG, 2006. All rights reserved