Siemens SINUMERIK 840Di Diagnostic Manual page 541

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

11/2006
61339
Channel %1 Block %2:Correction factor for rapid traverse speed = 0
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
Check parameter _SPEED[0] in GUD6.
61340
Channel %1 Block %2: Incorrect alarm number
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
Internal error in measuring cycles.
61341
Channel %1 block %2: Probe not calibrated in active plane.
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE974, CYCLE977, CYCLE978, CYCLE979.
Remedy:
Calibrate the probe prior to calling a cycle.
61342
Channel %1 Block %2: Invalid software version or wrong format entered
in GUD6
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
Lower than measuring cycle software 6.2:_SI[1] in GUD6 has no value or a value < 3
Higher than measuring cycle software 6.3: Upgrade NCK software version.
61343
Channel %1 Block %2: No tool available for specified tool identifier
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
Check name of tool identifier.
61344
Channel %1 Block %2: Several tools are active
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
Remove tool from another spindle.
61345
Channel %1 Block %2: Parameterized D number (_KNUM) too large
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
Reduce the D number in _KNUM, check software or MD of flat D number.