8100
Channel %1 block %2: function not possible
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
- Impossible due to embargo regulations:
- 1. Synchronous actions: Writing of feed, override and axial offsets ($AA_VC, $AC_VC, $AA_OVR,
$AA_VC and $AA_OFF) from synchronous actions as well as Continuous Dressing can be
programmed only once in a block.
- 2. Extended measurement: 'Cyclic measurement' (MEAC) and 'Measurement from synchronous
action' is not possible.
- 3. Axis interpolation: The number of axes interpolating with one another must not exceed 4 (this also
includes synchronous coupling of axes via synchronous actions "DO POS[X]=$A..." "DO
FA[X]=$A...").
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Modify part program.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
8101
Option for collision avoidance is inadequate
Definitions:
The option stage is inadequate for the desired function. Possible reasons:
1. More 3D protection zones have been created than is possible.
2. A protection zone type was requested that is not permitted.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
1. Buy an adequate option stage.
2. Reduce the number of 3D protection zones.
3. Avoid impermissible protection zone types.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
8120
Channel %1 block %2 following axis/spindle %3 generic coupling %4
required
Parameters:
%1 = Channel number
%2 = Block number
%3 = Slave axis
%4 = String
Definitions:
The option stage is inadequate for the desired function. Possible reasons:
More couplings have been created than are permitted.
The number of permissible leading axes has been exceeded for one or more couplings.
The range of functions of one or more couplings has not been released.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Buy an adequate option stage.
Reduce the number of simultaneously active couplings.
Reduce the number of leading axes per coupling or only use the released range of functions.
Program
Clear alarm with the RESET key. Restart part program
Continuation: