Overview of Alarms
NCK alarms
16938
Channel %1 action %2<ALNX> aborted due to active gear change
Parameters:
%1 = Channel ID
%2 = Action number/action name
Definitions:
Reorganization events are, among others, subprogram abort, delete distance-to- go and interrupts,
axis replacement, exiting the correction state. These events wait for the end of a gear change.
However, the maximum waiting period has elapsed.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Program must be aborted with Reset and, if necessary, GEAR_CHANGE_WAIT_TIME must be
increased.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
16939
Channel %1 action %2<ALNX> rejected due to active gear change
Parameters:
%1 = Channel ID
%2 = Action number/action name
Definitions:
Reorganization events that are possible in Stop state, e.g mode change, are waiting for the end of the
gear change. However, the maximum waiting period has elapsed.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Repeat action or increase MD GEAR_CHANGE_WAIT_TIME.
Program
Clear alarm with the Delete key or NC START.
Continuation:
16940
Channel %1 action %2<ALNX> wait for gear change
Parameters:
%1 = Channel ID
%2 = Action number/action name
Definitions:
Reorganization events are waiting for the end of a gear change. The alarm is displayed during the
waiting period.
Reaction:
Alarm display.
Warning display.
Remedy:
Alarm is suppressed by means of ENABLE_ALARM_MASK bit 1 == 0.
Program
Alarm display showing cause of alarm disappears. No further operator action necessary.
Continuation: