Siemens SINUMERIK 840Di Diagnostic Manual page 851

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

11/2006
No. 115
Explanation
The event is triggered by the positive PLC edge of the "Repos-Mode-Edge"signal.
Cause
The channel is active (program running, block search, loading machine data)
Remedy
Abort the program with the Reset key or stop the program (not with block search, loading
machine data).
No. 116
Explanation
Activate tool-management commands (Ch. VDI signal).
Cause
The NCK channel is in a state other than "ready".
Remedy
Abort the program or process with the Reset key or wait for end of program.
No. 117
Explanation
Deactivate tool-management commands (Ch. VDI signal).
Cause
The NCK channel is in a state other than "ready".
Remedy
Abort the program or process with the Reset key or wait for end of program.
No. 118
Explanation
Selection of desired safety limitations (SGE) (always allowed).
Cause
-
Remedy
-
No. 119
Explanation
Stop run, i.e., the NCK has automatically stopped at an OPI-defined block
Cause
1. SFC is not in automatic mode
Remedy
-
No. 120
Explanation
Rapid lift with a single axis
Cause
The axis is not controlled by the PLC
Remedy
-