Siemens SINUMERIK 840Di Diagnostic Manual page 807

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

11/2006
380072
Profibus DP: output slot for base address %1 (size %2) not allowed
Parameters:
%1 = Logical base address of the requested area
%2 = Size of the area in bytes
Definitions:
An incorrect logical base address was set for a digital or analog output, the area is resides in the
access range of the PLC (PIQ, base addresses < 256).
For length =1 it is a digital output,
For length =2 it is an analog output.
Reaction:
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Only use addresses >= 256 for output slots.
Enter correct base addresses in the machine data:
- For length=1: Correct machine data MN_HW_ASSIGN_DIG_FASTOUT.
- For length=2: Correct machine data MN_HW_ASSIGN_ANA_FASTOUT.
- NCK restart
If the error cannot be eliminated by this procedure, please make a note of the error text and contact
the control system manufacturer.
Program
Switch control OFF - ON.
Continuation:
380075
PROFIBUS DP: DP I/O failure bus %2 slave %1
Parameters:
%1 = Slave address
%2 = Number of the affected bus
Definitions:
Failure of a PROFIBUS slot used by the NCK for digital or analog I/O.
Reaction:
Alarm display.
Remedy:
Check that the PROFIBUS slave is operating correctly (all slaves must be included in the bus, green
LED).
Program
Alarm display showing cause of alarm disappears. No further operator action necessary.
Continuation:
380500
Profibus-DP: fault on drive %1, code %2, value %3, time %4
Parameters:
%1 = Axis
%2 = Fault code of drive (P824)
%3 = Fault value of drive (P826)
%4 = Fault time of drive (P948/P825)
Definitions:
Contents of fault memory of assigned drive.
Reaction:
Alarm display.
Remedy:
See drive documentation for fault codes/fault values.
Program
Alarm display showing cause of alarm disappears. No further operator action necessary.
Continuation:
380501
PROFIBUS DP: fault on bus,slave,DO-Id %1, code %2, value %3, time %4
Parameters:
%1 = 8 bit bus number, 8 bit slave number, 16 bit DO-ld
%2 = Fault code of drive (P947)
%3 = Fault value of the drive (P949)
%4 = Fault time of the drive (P948)
Definitions:
Contents of the fault memory of the assigned slave.
Reaction:
Alarm display.
Remedy:
See drive documentation for fault codes/fault values.
Program
Alarm display showing cause of alarm disappears. No further operator action necessary.
Continuation:
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
Overview of Alarms
SIMODRIVE alarms
2-807

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents