Siemens SINUMERIK 840Di Diagnostic Manual page 243

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

11/2006
14610
Channel %1 block %2 compensation block not possible
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
An alarm was output which could be eliminated basically via program correction. Since the error
occurred in a program which is processed from external, a compensation block/program correction is
not possible.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Abort program with reset.
- Correct program on MMC or PC.
- Restart reloading (possibly with block search and interrupt location).
Program
Clear alarm with the RESET key. Restart part program
Continuation:
14615
Channel %1 An error occurred while handling the function syntax check:
identifier %3
Parameters:
%1 = Channel number
%2 = Block number
%3 = Error code
Definitions:
An error occurred while handling the function syntax check via the PI services _N_CHKSEL,
_N_CHKRUN, _N_CHKABO and _N_SEL_BL. Parameter %3 describes the error situation more
closely:
Value
1: An invalid line number was transferred with the PI service _N_SEL_BL
2: An invalid line number for the range end was transferred with the PI service _N_CHKRUN
3: PI service _N_CHKSEL was activated although a block selection (PI service _N_SEL_BL) was
active for the selected program.
Reaction:
Alarm display.
Remedy:
Value
1: Supply PI service _N_SEL_BL with the correct line number
2: Supply PI service _N_CHKRUN with the correct line number for the range end
3: Ensure that the channel is in reset status before activating the PI service _N_CHKSEL.
Program
Clear alarm with the Delete key or NC START.
Continuation:
14650
Channel %1 block %2 SETINT instruction with invalid ASUP input
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Asynchronous subroutines are subroutines that are executed following a hardware input (interrupt
routine started by a rapid NCK input).
The NCK input number must lie between 1 and 8. It is assigned a priority from 1 to 128 (1 is the highest
priority) in the SETINT instruction with the keyword PRIO = ... .
Example:
If NCK input 5 changes to "1" the subroutine LIFT_Z should be started with the highest priority.
N100 SETINT (5) PRIO = 1 LIFT_Z
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Program the NCK input of the SETINT statement with a value of not less than 1 or greater than 8.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
Overview of Alarms
NCK alarms
2-243