Overview of Alarms
NCK alarms
61261
Channel %1 block %2: center offset too large
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The center offset on center drilling is larger than permissible.
Alarm triggered by following cycles: F_DRILL, F_DRILLD.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Enter smaller center offset (see display machine data 9862).
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61262
Channel %1 block %2: lead not possible with selected tool
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The lead of the tap does not match the programmed lead.
Alarm triggered by following cycles: F_DR_TAP, F_DRM_TA, F_TAP.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Use a tap with the programmed lead.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61263
Channel %1 Block %2: Chained ShopMill program blocks not permissible
in subprogram on pos. pattern
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
If a subroutine is called from a position pattern, the subroutine itself must not include a position pattern.
The alarm is triggered by the following cycle: E_MANAGE
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Reprogram machining.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61264
Channel %1 Block %2: Chained ShopTurn program blocks not
permissible in subprogram on pos. pattern
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
If a subroutine is called from a position pattern, the subroutine itself must not include a position pattern.
Alarm triggered by following cycle: F_MANAGE.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Reprogram machining.
Program
Clear alarm with the RESET key. Restart part program
Continuation: