7100
Compile cycles VDI area: %1 byte for inputs and %2 byte for outputs.
Maximum %3 bytes available.
Parameters:
%1 = String (machine data)
%2 = String (machine data)
%3 = Max. length for interface
Definitions:
The sum of the input and output bytes at the VDI user interface for the compile cycles exceeds the
maximum quantity of 400 bytes.
Reaction:
NC not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department. Set the machine data for dividing up the
VDI user interface of the compile cycles (DB 9) into input and output bytes in accordance with the
functions in the compile cycles. The maximum quantity of 400 bytes must not be exceeded. There are
no restrictions concerning the division into input and output bytes.
Program
Switch control OFF - ON.
Continuation:
7200
Problem with externally linked compile cycle %1 %2
Parameters:
%1 = Description string
%2 = Additional information
Definitions:
Problem with loadable compile cycles
Example:
"Version_conflict_with_CCNCKInterface_Version"
Meaning: The interface version of the compile cycle is incompatible with the NCK version.
"Loader_problem_from_dFixup"
Meaning: Unresolved references are left over after loading of all compile cycles, for example as an
ELD file is missing.
Reaction:
Alarm display.
Remedy:
See function description of the compile cycle!
Program
Clear alarm with the Delete key or NC START.
Continuation:
7201
Assertion error in %1 line %2
Parameters:
%1 = String (path with program name)
%2 = String (line number)
Definitions:
This alarm is purely a development alarm. It only occurs with externally linked compile cycles.
Reaction:
NC not ready.
The NC switches to follow-up mode.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Alarm reaction delay is canceled.
Remedy:
Consultation with CC developer
Program
Clear alarm with the RESET key in all channels. Restart part program.
Continuation: