11/2006
14090
Channel %1 block %2 invalid D number
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
A value less than zero has been programmed under address D.
A set of parameters with 25 correction values has been automatically assigned to each active tool.
Each tool can have 9 sets of parameters (D1 - D9, initial setting is D1). When the D number changes,
the new parameter set is active (D0 is used for deselecting the correction values).
N10 G.. X... Y... T15 ; Parameter set D1 of T15 active
N50 G.. X... D3 M..
N60 G.. X.. T20
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Program D numbers in the permissible value range (D0, D1 to D9).
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14091
Channel %1 block %2 illegal function, index %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Index
Definitions:
A function was programmed or triggered which is not allowed in the current program context. The code
of the function in question is entered in the "index" parameter:
Index == 1: "RET" command was programmed in the main program level
Index == 2: Conflict between "Cancel level"/"Clear number of passes" and "Implicit GET"
Index == 3: Conflict ASUB start immediately after selection of overstore (up to P3)
Index == 4: MD MN_G53_TOOLCORR = 1 : SUPA/G153/G53 programmed in G75
Index == 5: POSRANGE command not programmed in synchronized action
Index == 6: SIRELAY command not programmed in synchronized action
Index == 7: GOTOF/GOTOB/GOTO command programmed with string variable in synchronized
action.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Index == 1: Substitute "RET" command with M17/M30
Index == 2: Insert an auxiliary block (e.g. M99) after the subroutine call to which the "Cancel
level"/"Clear number of passes" refers
Index == 3: Overstore an auxiliary block (e.g. M99), then start ASUB (up to P3)
Index == 4: With MD MN_G53_TOOLCORR = 1: Do not activate SUPA/G53/G153 in the G75 block
Index == 5: Program POSRANGE command in synchronized action
Index == 6: Program SIRELAY command in synchronized action
Index == 7: Program GOTOF/GOTOB/GOTO command with block number or label
Program
Clear alarm with the RESET key. Restart part program
Continuation:
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
; Parameter set D3 of T15 active
; Parameter set D1 of T20 active
Overview of Alarms
NCK alarms
2-205