Siemens SINUMERIK 840Di Diagnostic Manual page 709

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

11/2006
300511
Axis %1 drive %2 measuring function active
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
The measuring function (e.g. frequency response measurement was active during the switching on
operation (power supply start-up active). Illegal activation of the measuring function may have
occurred internally.
Reaction:
NC not ready.
The NC switches to follow-up mode.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Channel not ready.
Remedy:
- Stop the measuring function
- NCK reset
Program
Switch control OFF - ON.
Continuation:
300512
Axis %1 drive %2 direct feedback recognized
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
The current rotor position and the position information read out by the encoder on ramp-up were
compared with each other and a deviation of more than 45 degrees was found.
Reaction:
NC not ready.
The NC switches to follow-up mode.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Channel not ready.
Remedy:
- The deviation points to a local contamination of the encoder or an erroneous or loose encoder
assembly. The encoder must be examined accordingly.
Operation may commence again only after successful error correction as there is a risk of
uncontrollable movements!
- NCK reset
Program
Switch control OFF - ON.
Continuation:
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
Overview of Alarms
SIMODRIVE alarms
2-709

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents