Siemens SINUMERIK 840Di Diagnostic Manual page 848

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

List of Action Numbers
No. 92
Explanation
Save interlock for data.
Cause
The channel is not in the "stopped" state.
Remedy
-
No. 93
Explanation
Activate user data, e.g., via MMC; newly modified tool lengths become active immedi-
ately in the running program
Cause
1. The channel is not in the "stopped" state.
2. The channel is stopped and the current block cannot be reorganized.
− Press the Stop/Single-Block/Reset/StopAtEnd (Automatic) key.
Remedy
− Activate a block change until the NC block can be reorganized.
No. 94
Explanation
Write the user PLC version to the version file.
Cause
-
Remedy
-
No. 95
Explanation
Switch measuring systems (PI command).
Cause
-
Remedy
-
No. 96
Explanation
Shut down system (VDI signal).
Cause
-
Remedy
-
No. 97
Explanation
Activate block search PI (program invocation) in mode 5. This mode simulates the block
search, in which the program under "Program test operation" is processed as far as the
target of the block search.
Cause
-
Remedy
-
3-848