Siemens SINUMERIK 840Di Diagnostic Manual page 241

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

11/2006
14550
Channel %1 block %2 contour tool: impermissible tool contour change.
Code no. %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Error code
Definitions:
A new tool with deviating tool contour was activated for contour tools on active tool radius
compensation
The error cause is explained further by an error code.
If the error code is an integer, the lower-value three decimal places specify the number of the edge,
in which the error was detected, while the thousandth digit explains the reason in more detail.
-1: The tool was deleted.
-2: The number of contour elements (edges) explaining the tool, has changed.
1000: The edge center has changed
2000: The edge radius has changed.
3000: The initial angle has changed.
4000: The final angle has changed.
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Change NC program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14551
Channel %1 block %2 contour tool: angle area of edge D%3 larger than
359 degrees
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Edge number, label
Definitions:
A single edge must cover a max. angle area of 359 degrees.
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Check tool definition.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14600
Channel %1 block %2 reload buffer %3 cannot be established
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = File name
Definitions:
The download buffer for "execute from external" could not be created. Possible causes:
- Not enough memory available (for minimum see MD $MN_MM_EXT_PROG_BUFFER_SIZE)
- No resources available for MMC NCK communication (see MD $MN_MM_EXT_PROG_NUM)
- The file already exists
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Release memory, e.g. by deleting part programs
- Modify MD $MN_MM_EXT_PROG_BUFFER_SIZE and/or $MN_MM_EXT_PROG_NUM.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
Overview of Alarms
NCK alarms
2-241

Hide quick links:

Advertisement

Table of Contents
loading