27223
PROFIsafe: NCK F module MD %1[%2] is not a %3 module
Parameters:
%1 = MD name
%2 = MD array index
%3 = Module type
Definitions:
The F module parameterized in the specified NCK MD has not been entered as input/output module
in the S7 PROFIBUS configuration.
- %3 = INPUT: NCK F parameterization expects INPUT module
- %3 = OUTPUT: NCK F parameterization expects OUTPUT module
- %3 = IN/OUT: NCK F parameterization expects INPUT or OUTPUT module
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Check the module in the S7 PROFIBUS configuration.
Program
Switch control OFF - ON.
Continuation:
27224
PROFIsafe: F module MD %1[%2] - MD %3[%4]: double assignment of
PROFIsafe address
Parameters:
%1 = MD name 1
%2 = MD array index 1
%3 = MD name 2
%4 = MD array index 2
Definitions:
In the NCK MD or in the S7 F parameters, the same PROFIsafe address has been parameterized for
the F modules parameterized in the specified machine data. Therefore, no clear communication link
is possible between F master and F slave.
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Check and correct the S7 F parameterization and NCK MD.
Program
Switch control OFF - ON.
Continuation:
27225
PROFIsafe: slave %1, configuration error %2
Parameters:
%1 = PROFIBUS slave address
%2 = Configuration error
Definitions:
An error occurred during the evaluation of the S7 PROFIBUS configuration for the specified slave.
This is further specified in alarm parameter %2.
%2 = PRM header: the PRM telegram for this slave could not clearly be interpreted.
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Check and correct the S7 PROFIBUS configuration.
Program
Switch control OFF - ON.