List of Action Numbers
No. 24
Explanation
Start program processing (VDI signal: NC Start).
Cause
1. Program status active
2. An alarm reaction is pending which prevents a start or forces braking
3. Reference point approach has not been performed yet.
− Execute condition for clearing alarm
Remedy
− Reference point approach
No. 25
Explanation
Start program processing (channel communication, NC block: Start).
Cause
1. Program status active.
2. An alarm reaction is pending which prevents a start or forces braking
3. Reference point approach has not been performed yet.
4. An incorrect operating mode has been selected. (only Automatic).
− Protect Start with WAITE
Remedy
− Execute condition for clearing alarm
− Reference point approach
− Select program operating mode
No. 26
Explanation
Start continuation of program processing (VDI signal: NC Start).
Cause
1. Program status active
2. An alarm reaction is pending which prevents a start or forces braking
3. Reference point approach has not been performed yet.
− Execute condition for clearing alarm.
Remedy
− Reference point approach
No. 27
Explanation
Start continuation of the selected process (JOG, reference point or digitizing) (VDI sig-
nal: NC Start).
Cause
1. Jog motion active
2. An alarm reaction is pending which prevents a start or forces braking
Remedy
Execute condition for clearing alarm
3-836