11/2006
14800
Channel %1 block %2 programmed path speed less or equal to zero
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
A negative F value has been programmed in conjunction with the G functions G93, G94, G95 or G96.
The path velocity may be programmed in the range 0.001 to 999 999.999 [mm/min, mm/rev, deg/min,
deg/rev] for the metric input system and 0.000 1 to 39 999.999 9 [inch/min, inch/rev] for the inch input
system.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Program the path velocity (geometric sum of the velocity components of the geometry axes involved)
within the limits given above.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14810
Channel %1 block %2 negative axis speed programmed for positioning
axis %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis
Definitions:
A negative feed (FA value) has been programmed for the displayed axis presently operating as a
positioning axis. The positioning velocity may be programmed in the range 0.001 to 999 999.999
[mm/min, deg/min] for the metric input system and 0.000 1 to 39 999.999 9 [inch/min, inch/rev] for the
inch input system.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Program the positioning velocity within the limits given above.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14811
Channel %1 block %2 incorrect value range for acceleration of
axis/spindle %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis, spindle
Definitions:
A value outside of the permissible input range of the programmed acceleration has been used. Values
of between 1 and 200 % are possible.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Adjust the value range in accordance with the Programming Guide. Values of 1 ... 200% are allowed.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
© Siemens AG, 2006. All rights reserved