Siemens SINUMERIK 840Di Diagnostic Manual page 535

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

11/2006
61300
Channel %1 Block %2: Probe defective
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61301
Channel %1 Block %2: Probe not switching
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The measuring distance was completely traversed but no switching signal was generated at the
measuring input.
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
-Check measuring input.
-Check measuring distance.
-Probe defective.
61302
Channel %1 Block %2: Probe - collision
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The measuring probe collided with an obstacle when being positioned.
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
? Check spigot diameter (may be too small)
? Check measuring distance (may be to long)
61303
Channel %1 Block %2: Safety margin exceeded
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The measuring result differs greatly from the specified value.
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
-Check setpoint value.
-Increase parameter _TSA.
61304
Channel %1 Block %2: Allowance
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program
Clear alarm with the RESET key. Restart part program
Continuation:
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
Overview of Alarms