Overview of Alarms
NCK alarms
4631
Invalid handwheel slot for handwheel %1
Parameters:
%1 = Handwheel slot
Definitions:
The handwheel slot for handwheel %1 requested through the machine date
$MN_HANDWHEEL_INPUT is not available for PROFIBUS handwheels.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Configure machine date $MN_HANDWHEEL_INPUT to a valid handwheel slot for the corresponding
PROFIBUS handwheel.
Program
Switch control OFF - ON.
Continuation:
4632
Logical PROFIBUS handwheel slot base address for handwheel %1 not
found
Parameters:
%1 = Handwheel number
Definitions:
The logical base address of the PROFIBUS handwheel slot in machine date array
$MN_HANDWHEEL_LOGIC_ADDRESS[] indexed in machine date $MN_HANDWHEEL_MODULE
was not found.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Check if $MN_HANDWHEEL_MODULE of the corresponding handwheel is correct. Check if indexed
logical base address of PROFIBUS handwheel slot in machine date array
$MN_HANDWHEEL_LOGIC_ADDRESS[] is correct.
Program
Switch control OFF - ON.
Continuation:
4700
PROFIBUS I/O: The logical slot / I/O area address %1 was not found.
Parameters:
%1 = Area address
Definitions:
The logical slot / I/O area address was not found in the machine data MD10500
$MN_DPIO_LOGIC_ADDRESS_IN with the stated slot/ I/O area.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Check the slot / I/O area address in the configuration (STEP 7, HW Config).
Program
Switch control OFF - ON.
Continuation:
4702
PROFIBUS I/O: The logical slot / I/O area address %1 was not found.
Parameters:
%1 = Area address
Definitions:
The logical slot / I/O area address was not found in the machine data MD10506
$MN_DPIO_LOGIC_ADDRESS_OUT with the stated slot / I/O area index.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Check the slot / I/O area address in the configuration (STEP 7, HW Config).
Program
Switch control OFF - ON.
Continuation:
2-64