Siemens SINUMERIK 840Di Diagnostic Manual page 265

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

11/2006
15100
Channel %1 block %2 REORG abort caused by log file overflow
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
In order to synchronize the preprocessing run and the main run with REORG, the control accesses
modification data which are maintained in a logfile. The alarm indicates that no more capacity is
available in the logfile for the specified block in the channel.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. No remedial measures are available for
the further execution of the current part program, however:
1. Reduce log file size requirement by:
Reducing the distance between the preprocessing and the main run via appropriate preprocessing
stops STOPRE.
2. Increase the size of the logfile by means of the channel-specific machine data:
Modify MD 28000: MM_REORG_LOG_FILE_MEM and
Modify MD 28010: MM_NUM_REORG_LUD_MODULES
Program
Clear alarm with the RESET key. Restart part program
Continuation:
15110
Channel %1 block %2 REORG not possible
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
In order to synchronize the preprocessing run and the main run with REORG, the control accesses
modification data which are maintained in a logfile. The alarm indicates that no more capacity is
available in the logfile for the specified block in the channel.
The alarm message means that the logfile has been deleted in order to obtain additional memory for
program reorganization. Consequently, it is no longer possible to REORG the preprocessing memory
up to the next coincidence point.
Reaction:
Alarm display.
Remedy:
Please inform the authorized personnel/service department. No remedial measures are available for
the further execution of the current part program, however:
1. Reduce log file size requirement by:
Reducing the distance between the preprocessing and the main run via appropriate preprocessing
stops STOPRE.
2. Increase the size of the logfile by means of the channel-specific machine data:
Modify MD 28000: MM_REORG_LOG_FILE_MEM and
Modify MD 28010: MM_NUM_REORG_LUD_MODULES
Program
Alarm display showing cause of alarm disappears. No further operator action necessary.
Continuation:
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition