Siemens SINUMERIK 840Di Diagnostic Manual page 587

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

11/2006
62918
Channel %1 block %2: Rapid traverse within contour definition
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
--
Program
Clear alarm with the RESET key. Restart part program
Continuation:
62919
Channel %1 block %2: Nominal radius parameter is missing
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
--
Program
Clear alarm with the RESET key. Restart part program
Continuation:
62920
Channel %1 block %2: Pocket surface not specified
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
--
Program
Clear alarm with the RESET key. Restart part program
Continuation:
62921
Channel %1 block %2: Pocket depth not specified
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
--
Program
Clear alarm with the RESET key. Restart part program
Continuation:
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
Overview of Alarms
NCK alarms
2-587