Overview of Alarms
NCK alarms
16120
Channel %1 block %2 invalid index for tool fine compensation
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Mistake in programming: The 2nd parameter in the PUTFTOC command indicates for which tool
parameter the value is to be corrected (1 - 3 tool lengths, 4 tool radius). The programmed value is
beyond the permitted range.
Permissible values are 1 - 4 if on-line tool radius compensation is allowed (see machine data
ONLINE_CUTCOM_ENABLE), otherwise values 1 - 3.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program: Length 1 - 3 or 4 permissible for radius.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16130
Channel %1 block %2 instruction not allowed with FTOCON
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
- Case 1: A plane change is not allowed if the modal G function FTOCON: "fine tool compensation" is
active.
- Case 2: Transformation selection is allowed only for zero transformation or transformation inclined
axis, Transmit or Tracyl if FTOCON is active.
- Case 3: Tool change is not allowed with M06 if FTOCON has been active since the last tool change.
- Case 4: Orientable tool holder is active.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program: Deselect fine tool compensation with FTOCOF.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16140
Channel %1 block %2 FTOCON not allowed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The tool fine compensation (FTOC) is not compatible with the currently active transformation.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program: Deselect fine tool compensation with FTOCOF.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16150
Channel %1 block %2 invalid spindle number with PUTFTOCF
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The spindle number programmed for PUTFTOC or PUTFTOCF is beyond the permitted range for the
spindle numbers.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program. Is the programmed spindle number available?
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation: