14133
Channel %1 block %2 G code for orientation definition not allowed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
It is only possible to program a G code of the 50th G code group if machine data
ORI_DEF_WITH_G_CODE is set to TRUE.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Adapt machine data.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
14134
Channel %1 block %2 G code for orientation interpolation not allowed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
It will only be possible to program a G code of the 51st G code group, if machine data
ORI_IPO_WITH_G_CODE has been set to TRUE.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Adapt machine data.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
14136
Channel %1 block %2 Orientation polynomial is not permitted
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Programming of orientation polynomials both for the angles (PO[PHI], PO[PHI]) and for the
coordinates of a reference point on the tool (PO[XH], PO[YH], PO[ZH]) is not permitted. Orientation
polynomials can only be programmed, if an orientation transformation is active and the orientation is
changed by interpolating the vector (ORIVECT, ORICONxxx, ORICURVE), i.e. the orientation must
not be changed by interpolating the axis (ORIAXES).
Reaction:
Correction block is reorganized.
Interpreter stop
Interface signals are set.
Alarm display.
Remedy:
Modify the NC program
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14137
Channel %1 block %2 Polynomials PO[PHI] and PO[PSI] are not
permitted
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
A polynomial for the angles PHI and PSI can only be programmed, if the orientation is interpolated in
the plane between start and end orientation (ORIVECT, ORIPLANE) or on a taper (ORICONxxx). If
interpolation type ORICURVE is active, no polynomials can be programmed for angles PHI and PSI.
Reaction:
Correction block is reorganized.
Interpreter stop
Interface signals are set.
Alarm display.
Remedy:
Modify the NC program
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation: