11/2006
14430
Channel %1 block %2 tangential axis %3 must not be traversed as POS
axis
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name
Definitions:
A tangentially followed-up axis cannot be traversed as positioning axis.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Change part program and delete active tangential control with TANGDEL.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14432
Channel %1 block %2 rounding length for tangential axis %3 is zero.
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name
Definitions:
For a tangential axis that is coupled during preparation, a rounding length must be indicated with
TANGON() on activating the tangential control, or possibly occuring discontinuities of the tangential
axis cannot be smoothed.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14434
Channel %1 block %2 rel. lift-off path for tangential axis %3 is invalid
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name
Definitions:
Factor r as programmed on TLIFT for the relative lift-off path must be within range 0 =< r < 1.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14500
Channel %1 block %2 illegal DEF or PROC instruction in the part
program
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
NC part programs with high-level language elements are divided into a preceding definition part
followed by a program part. The transition is not marked specifically; a definition statement is not
allowed to follow the 1st program command.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Put definition and PROFC statements at the beginning of the program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
Overview of Alarms