Siemens SINUMERIK 840Di Diagnostic Manual page 512

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

Overview of Alarms
NCK alarms
61191
Channel %1 block %2: 5 axis transformation not set up
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The alarm is triggerd by the following cycles: CYCLE832.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
--
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61192
Channel %1 block %2: second 5 axis transformation not set up
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The alarm is triggerd by the following cycles: CYCLE832.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
--
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61193
Channel %1 block %2: compressor option not set up
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The alarm is triggerd by the following cycles: CYCLE832.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
--
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61194
Channel %1 block %2: spline interpolation option not set up
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The alarm is triggerd by the following cycles: CYCLE832.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
--
Program
Clear alarm with the RESET key. Restart part program
Continuation:
2-512
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
11/2006

Hide quick links:

Advertisement

Table of Contents
loading