Siemens SINUMERIK 840Di Diagnostic Manual page 90

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

Overview of Alarms
NCK alarms
8022
Option 'activation of more than %1KB SRAM' not set
Parameters:
%1 = Memory size
Definitions:
The option for memory extension does not correspond to the active SRAM.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department.
- Buy option
- Activate less SRAM
Program
Switch control OFF - ON.
Continuation:
8023
Option 'Activation of more than %1 KB PLC user memory' not set
Parameters:
%1 = Memory size
Definitions:
The option for the memory configuration does not correspond to the PLC user memory used.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department.
- Purchase option
- Use less PLC user memory
Program
Switch control OFF - ON.
Continuation:
8030
Channel %1 block %2 option 'interpolation of more than 4 axes' not set
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The option for the number of interpolating axes does not correspond to the number of axes
programmed in the interpolation group.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Option: "Interpolation of more than 4 axes" (the number of axes that is then allowed can be set in this
option) or specify in the part program as many (or fewer, as required) axes corresponding to the
configuration of the control.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
8032
Option 'activation of more than %1 link axes' not set
Parameters:
%1 = Number of axes
Definitions:
The option for the number of link axes does not match the number of axes programmed in MD
$MN_AXCONF_LOGIC_MACHAX_TAB.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Buy option
- Configure fewer link axes
Program
Clear alarm with the RESET key. Restart part program
Continuation:
2-90
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
11/2006

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents