10658
Channel %1 axis %2 impermissible axis status.
Parameters:
%1 = Channel number
%2 = Error ID and gantry unit.
Definitions:
%2 error ID and gantry unit
- %2 = 30XX => gantry group cannot be closed, as not all gantry axes
- %2 = 40XX => gantry group cannot be closed, as the gantry axes
- %2 = 50XX => gantry group is to change the channel due to a PLC request;
- %2 = 60XX => gantry group is to be transferred to channel due to an NC program request,
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Error ID:
- %2 = 30XX => assign all gantry axes to the current channel, for example via axis change.
- %2 = 40XX => set all axes of the gantry group to the same axis state,
- %2 = 50XX => make all gantry axes known to the required channel.
- %2 = 60XX => make all gantry axes known to the required channel.
:end
Program
Clear alarm with the RESET key. Restart part program
Continuation:
10700
Channel %1 block %2 NCK protection zone %3 violated during automatic
or MDI mode
Parameters:
%1 = Channel number
%2 = Block number
%3 = Protection zone number
Definitions:
The workpiece-related NCK protection zone has been violated. Note that another tool-related
protection zone is still active. The workpiece-related protected area can be traversed after a new NC
Start.
Reaction:
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Protection zone can be traversed after a new NC Start.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
10701
Channel %1 block %2 channel-specific protection zone %3 violated
during automatic or MDI mode
Parameters:
%1 = Channel number
%2 = Block number
%3 = Protection zone number
Definitions:
The workpiece-related channel-specific protection zone has been violated. Note that another tool-
related protection zone is still active. The workpiece-related protected area can be traversed after a
new NC Start.
Reaction:
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Protection zone can be traversed after a new NC Start.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
are available in one channel.
have different axis states; the axis is assigned to the PLC, for example.
not all gantry axes are known in the new channel.
but the channel does not know all the gantry axes.
for example assign all axes to the NC program, or assign all axes to the PLC.