Overview of Alarms
NCK alarms
12560
Channel %1 block %2 programmed value %3 exceeds allowed limits
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Source string
Definitions:
In a value assignment, the permissible value range of the data type has been exceeded.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM
CORRECT. The correction pointer positions on the incorrect block.
Assign value within the value range of the various data types, or if necessary use another type in order
to increase the size of the value range, e.g. INT ->REAL.
Value ranges of the various variable types:
- REAL: Property: Fractional number with dec. pt., value range: +/-(2-1022-2+1023)
- INT: Property: Integers with signs, value range: +/-(231-1)
- BOOL: Property: Truth value TRUE, FALSE, value range: 0,1
- CHAR: Property: 1 ASCII character, value range: 0-255
- STRING: Property: Character string (max. 100 values), value range: 0-255
- AXIS: Property: Axis addresses, value range: Axis names only
- FRAME: Property: Geometric information, value range: As for axis paths
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
12570
Channel %1 block %2 too many motion synchronous actions in %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Source symbol
Definitions:
No more than 16 actions are allowed in a block with motion synchronous action.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Reduce the number of programmed actions.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
12571
Channel %1 block %2 %3 not permissible for motion synchronous action
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Source symbol
Definitions:
The predefined subprogram %3 specified here is not allowed in a block with motion synchronous
action. It may only be contained in a "normal" block.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify program.
Program
Clear alarm with NC START or RESET key and continue the program.