Overview of Alarms
NCK alarms
16000
Channel %1 block %2 invalid value for lifting direction
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
During the "rapid lift from contour" (keyword: LIFTFAST), a code value for the lifting direction
(keyword: ALF=...) which lies outside the permissible range (permissible value range: 0 to 8) was
programmed .
With active cutter radius compensation:
Code numbers 2, 3 and 4 cannot be used in G41
Code numbers 6, 7 and 8 cannot be used in G42 because they code the direction to the contour.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Program the lifting direction under ALF=... within the permissible limits.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16005
Channel %1 block %2 invalid value for lifting distance
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Mistake in programming: the value for the lifting path must not be negative.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16010
Channel %1 block %2 machining stop after lift fast
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
LIFTFAST without interrupt routine (Asup) has been programmed. The channel is stopped after the
lift motion has been carried out.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
After the channel stop, the axes must be retracted manually in JOG and the program aborted with
Reset.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
16015
Channel %1 block %2 wrong axis identifier %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name
Definitions:
Axis names from different coordinate systems were used to program axes for LIFTFAST. The
retraction movement is no longer clear.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Use axis names from one coordinate system.
Program
Clear alarm with NC START or RESET key and continue the program.