NCK alarms
14037
Channel %1 block %2 involute: radius invalid
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
With involute interpolation, the programmed radius of the basic circle must be greater than zero.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14038
Channel %1 block %2 involute not definable: end point error
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The programmed end point does not lie on the involute defined by the start point, radius and center
point of the basic circle. The deviation of the effective end radius from the programmed value is greater
than the permissible value specified in MD INVOLUTE_RADIUS_DELTA.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14039
Channel %1 block %2 involute: end point programmed several times
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
With involute interpolation, either the end point with the geometry axis identifiers or the angle of
rotation with AR=value can be programmed. Simultaneous programming of end point and angle of
rotation in one block is not allowed, since the end point can thus not be defined exactly.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
2-200