NCK alarms
61409
Channel %1 block %2: set up offsets not present
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
Set MD 18112, Bit 4=1
61410
Channel %1 block %2: option or offset value not present
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
The variable to be corrected requires an option or an increase in MD values.
61411
Channel %1 block %2: frame calculation impossible, check values
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE997, CYCLE119
Remedy:
Check the setpoint and actual values
61412
Channel %1 block %2: channel basic frame not present
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE997, CYCLE119
Remedy:
Set MD 28081>0, $P_CHBFRMASK>0
61413
Channel %1 block %2: check setpoint of ball diameter, _SETVAL<=0
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE997
Remedy:
Check setpoint value of spherical diameter.
61414
Channel %1 block %2 : distortion of triangle over limit
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE997, CYCLE119
Remedy:
Check the setpoint and actual values
61415
Channel %1 block %2: check probe / machining plane
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE971
Remedy:
Enter permissible probe (_TP[x,8], _TPW[x,8]) for machining plane or change machining plane.
61416
Channel %1 block %2: adapt array size %4!
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
"Adjust field size _TP[ ]/_CVAL[0]!" or "Adjust field size _WP[ ]/_CVAL[1]!" or "Adjust field size _KP[
]/_CVAL[2]!" or "Adjust field size _TWP[ ]/_CVAL[3]!". Check probe/machining plane.
Alarm triggered by following measuring cycles: all measuring cycles.
Remedy:
Adjust _CVAL entry with the number of available probe or calibration block data fields.