Overview of Alarms
SIMODRIVE alarms
380502
PROFIBUS DP: bus %1, slave %2 configuration changed
Parameters:
%1 = Bus number
%2 = Slave address
Definitions:
The PB bus configuration has changed.
Causes:
- Initial start-up
- New PB slave recognized on the bus
Reaction:
Interface signals are set.
Alarm display.
Remedy:
In order to operate the bus with the new configuration, an additional restart will be required.
Program
Switch control OFF - ON.
Continuation:
380503
PROFIBUS DP: bus %1 configuration changed
Parameters:
%1 = Bus number
Definitions:
A new SDB2000 with a modified configuration was provided.
The new settings will be activated only at the next ramp-up of PROFIBUS.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
In order to operate the bus with the new configuration, an additional restart will be required.
Program
Switch control OFF - ON.
Continuation:
2-808