Siemens SINUMERIK 840Di Diagnostic Manual page 826

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

Overview of Alarms
PLC alarms
411101
Impermissible Parameter Axis in FB11
Definitions:
Axis parameter not within the permissible range.
Reaction:
Alarm display.
Remedy:
Use permissible axis number.
Program
Internal
Continuation:
411501
Incorrect version of FB 15, > general reset, do not transmit FB 15 from
project
Definitions:
FB 15 does not match the basic program used.
Reaction:
Alarm display.
Remedy:
General PLC reset. Use correct version of the basic program.
Program
Internal
Continuation:
411502
Incorrect basic PLC program version
Definitions:
FB 15 does not match the basic program used.
Reaction:
Alarm display.
Remedy:
Load the basic program that matches the NCK version.
Program
Internal
Continuation:
428201
Diagnostic alarm
Definitions:
OB82 or OB86 has been triggered.
Reaction:
Alarm display.
Remedy:
Rectify the cause of the error displayed
Program
Switch control OFF - ON.
Continuation:
428221
Diagnostic alarm from diagnostics address %Z
Definitions:
OB82 or OB86 has been triggered.
Reaction:
Alarm display.
Remedy:
Rectify the cause of the error displayed
Program
Switch control OFF - ON.
Continuation:
428601
Module failure of the expansion unit
Definitions:
OB82 or OB86 has been triggered.
Reaction:
Alarm display.
Remedy:
Rectify the cause of the error displayed
Program
Switch control OFF - ON.
Continuation:
428602
Recurrence of module failure of the expansion unit
Definitions:
OB82 or OB86 has been triggered.
Reaction:
Alarm display.
Remedy:
Rectify the cause of the error displayed
Program
Switch control OFF - ON.
Continuation:
2-826
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
11/2006

Hide quick links: