Overview of Alarms
NCK alarms
14414
Channel %1 block %2 GEOAX function: incorrect call
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The parameters for the GEOAX(...) call are incorrect. Possible causes:
- Uneven number of parameters.
- More than 6 parameters were specified.
- A geometry axis number was programmed which was smaller than 0 or greater than 3.
- A geometry number was programmed more than once.
- An axis identifier was programmed more than once.
- An attempt was made to assign a channel axis to a geometry axis which has the same name as one
of the channel axes.
- An attempt was made to remove a geometry axis from the geometry axis grouping and the geometry
axis has the same name as one of the channel axes.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program or correction block.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14415
Channel %1 block %2 tangent control: changeover geometry/channel
axis not allowed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
An assignment change of the geometry axes to channel axes is not permitted with active tangential
control.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Change part program and delete active tangential control with TANGDEL.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14420
Channel %1 block %2 index axis %3 frame not allowed
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis
Definitions:
The axis is to be traversed as an indexing axis, but a frame is active. This is not allowed by machine
data FRAME_FOR_CORRPOS_NOTALLOWED.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Modify part program. Change machine
data CORR_OR_AXIS_NOT_ALLOWED.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation: