Siemens SINUMERIK 840Di Diagnostic Manual page 221

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

11/2006
14154
Channel %1 block %2 The amount of fine correction in parameter %3of
the orientable toolholder %4 is too large
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Invalid parameter of the orientable toolholder
%4 = Number of the orientable toolholder
Definitions:
The maximum permissible value of the fine correction in an orientable toolholder is limited by the
machine data $MC_TOCARR_FINE_LIM_LIN for linear variables, and by the machine data
$MC_TOCARR_FINE_LIM_ROT for rotary variables. The alarm can only occur if the setting data
$SC_TOCARR_FINE_CORRECTION is not equal to zero.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Enter a valid fine correction value.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14155
Channel %1 block %2 invalid base frame definition for tool carrier offset
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
If a tool carrier selection causes a change in the table offset, a valid base frame must be defined in
order to store this offset; for more information see machine data 20184
(TOCARR_BASE_FRAME_NUMBER).
Reaction:
Correction block is reorganized.
Interpreter stop
Interface signals are set.
Alarm display.
Remedy:
Change the NC program or machine data 20184 (TOCARR_BASE_FRAME_NUMBER).
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14156
Channel %1 toolholder selection error at reset
Parameters:
%1 = Channel number
Definitions:
The settings in RESET_MODE_MASK require that an active orientable toolholder is maintained after
the reset. This is done by deselecting the old orientable toolholder and then reselecting it with data
that may have been modified. If an error occurs during the reselection, this alarm is issued (as a
warning) and then an attempt is made to select the orientable toolholder in the initial setting. If this
second attempt is successful, the reset cycle is continued without any further alarms.
Typically, the alarm only occurs when the old orientable toolholder has been selected with TCOFR,
and its axis directions have been changed in such a way before the reset that a setting suitable for the
associated frame is no longer possible. If there is another cause for the alarm, this results in an alarm
also being issued when attempting to select in the initial setting. This is then also displayed in plain
text.
Reaction:
Alarm display.
Remedy:
Check the program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
Overview of Alarms
NCK alarms
2-221

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents