18201
Channel %1 block %2 curve table: table %3 does not exist
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Number of curve table
Definitions:
An attempt was made to use a curve table whose table number is not known in the system \par.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Change the table number in the program instruction or define the curve table with the desired table
number.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
18202
Channel %1 block %2 curve table: instruction CTABEND without
CTABDEF not allowed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The CTABEND instruction, which is used to terminate the definition, has been programmed in the
program without starting a curve table definition with CTABDEF, or the CTABDEF and CTABEND
instructions were not programmed in the same program level.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Remove the CTABEND command or add the CTABDEF( ..) command at the appropriate program
location. The CTABDEF and CTABEND instructions must be programmed in the same program level
(main or subprogram). Start the program again.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
18203
Channel %1 block %2 curve table: instruction CTABDEF not within
CTABDEF
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
In the program, the instruction CTABDEF that starts the definition of curve tables, is programmed
within the definition part of a curve table. This is not allowed, as the current curve table must be
completed with CTABEND first.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Remove command CTABEND from program or insert instruction CTABDEF ( ..) in the relevant
program position. Instructions CTABDEF and CTABEND must be programmed in the same program
level (main program or subroutine). Restart the program.
Program
Clear alarm with the RESET key. Restart part program
Continuation: