Overview of Alarms
NCK alarms
14510
Channel %1 block %2 PROC instruction missing on subroutine call
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
In subroutine calls with parameter transfer ("call-by-value" or "call-by-reference") the called subroutine
must begin with a PROC statement.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Define the subroutine in accordance with the type used.
1. Conventional subroutine structure (without parameter transfer):
% SPF 123456
:
M17
2. Subroutine structure with keyword and subroutine name (without parameter transfer):
PROC UPNAME
:
M17
ENDPROC
3. Subroutine structure with keyword and subroutine name (with parameter transfer "call-by-value"):
PROC UPNAME (VARNAME1, VARNAME2, ...)
:
M17
ENDPROC
4. Subroutine structure with keyword and subroutine name (with parameter transfer "call-by-
reference"):
PROC UPNAME (Typ1 VARNAME1, Typ2 VARNAME2, ...)
:
M17
ENDPROC
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14520
Channel %1 block %2 illegal PROC instruction in data definition section
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The PROC statement may only be programmed at the beginning of the subroutine.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify NC part program appropriately.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
2-236
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition