Siemens SINUMERIK 840Di Diagnostic Manual page 24

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

Overview of Alarms
NCK alarms
2192
No NCU link module exists, MD %1 reset
Parameters:
%1 = String: MD identifier
Definitions:
An attempt was made to activate the NCU link functionality but the hardware is not available. The MD
was reset. Only occurs with the NCU link system
Reaction:
NC not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Install the hardware module and activate the function again (MD).
Program
Switch control OFF - ON.
Continuation:
2193
'Safety Integrated' is not available for link axis %1.
Parameters:
%1 = Machine axis index
Definitions:
The "Safety Integrated" function is not available for a link axis. Only occurs with the NCU link system
Reaction:
NC not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Use "Safety Integrated" function for local axes only.
Program
Switch control OFF - ON.
Continuation:
2194
Link axis active and $MN_MM_SERVO_FIFO_SIZE != 3
Definitions:
At least one axis is to be distributed via NCU link, then the machine data
$MN_MM_SERVO_FIFO_SIZE must be 3. Occurs only with an NCU link system.
Reaction:
NC not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Set $MN_SERVO_FIFO_SIZE to 3.
Program
Switch control OFF - ON.
Continuation:
2195
Channel %1 axis %2 high-speed punching/nibbling not possible via link
Parameters:
%1 = Channel number
%2 = Axis name, spindle number
Definitions:
An attempt was made to activate high-speed nibbling or punching for an axis programmed on a
different NCU than the drive.
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Channel not ready.
Remedy:
High-speed nibbling and punching is only supported on one NCU.
Program
Clear alarm with the RESET key in all channels of this mode group. Restart part program.
Continuation:
2-24
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition