14280
Channel %1 block %2 polar coordinates programmed incorrectly
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The end point of the displayed block has been programmed both in the polar coordinate system (with
AP=..., RP=...) and in the Cartesian coordinate system (axis addresses X, Y,...).
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Correct the NC part program - the axis motion may be specified in one coordinate system only.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14290
Channel %1 block %2 polynominal degree greater than 5 programmed
for polynominal interpolation
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
A polynominal degree greater than five was programmed for the polynominal interpolation. You can
only program polynomials up to the 5th degree.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14300
Channel %1 block %2 overlaid handwheel motion activated incorrectly
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Handwheel override has been called up incorrectly:
- 1. For positioning axes:
- Handwheel override programmed for indexing axes,
- No position programmed,
- FA and FDA programmed for the same axis in the block.
- 2. For contouring axes:
- No position programmed,
- G60 not active,
- 1. 1st G group incorrect (only G01 to CIP).
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14310
Handwheel %1 configuration incorrect or inactive
Parameters:
%1 = Handwheel number
Definitions:
- The inputs are using a drive with a drive number that does not exist or
- an inactive drive for assignment of the handwheel (ENC_HANDWHEEL_MODULE_NR) or
- an axis is using a measuring circuit which does not exist for the drive hardware.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Check input configuration (machine data)
and/or drive hardware. Power-up is interrupted.
Program
Switch control OFF - ON.
Continuation:
© Siemens AG, 2006. All rights reserved