Siemens SINUMERIK 840Di Diagnostic Manual page 536

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

Overview of Alarms
NCK alarms
61305
Channel %1 Block %2: Dimension too small
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61306
Channel %1 Block %2: Permissible measuring difference exceeded
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm triggered by following cycles: CYCLE971, CYCLE972, CYCLE974, CYCLE977, CYCLE978,
CYCLE979, CYCLE982, CYCLE994.
Remedy:
-Check setpoint value
-Increase parameter _TDIF
61307
Channel %1 Block %2: Incorrect measuring variant
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
The value of parameter _MVAR is impermissible.
61308
Channel %1 Block %2: Check measuring path _FA
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
A traversing path for measuring was generated whose size was specified by parameter _FA that
describes the maximum distance before and after the switching position (workpiece edge) and that
must have a value greater than 0.
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
Check parameter _FA.
61309
Channel %1 Block %2: Check probe type
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Probe type: 3D probe inactive.
This alarm is generated by all cycles except for CYCLE971, CYCLE972, CYCLE982.
Remedy:
The probe has to be of the "3D probe" type in the tool management.
Tool type of the workpiece probe in the TO memory is impermissible.
For CYCLE971: no permissible tool probe type entered in _TP[x,8], or check
the permissible working plane G17...G19 for tool type "Wheel".
61310
Channel %1 Block %2: Scale factor is active
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Scale factor = scaling is active.
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
Switch off the active scale factor in the program. Measuring is not possible with an active scale factor.
2-536
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
11/2006

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents