Siemens SINUMERIK 840Di Diagnostic Manual page 68

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

Overview of Alarms
NCK alarms
6035
Instead of %1 KB the system has only %2 KB of free user memory of type
'%3'
Parameters:
%1 = Free memory capacity in KB defined for the control model
%2 = Actual maximum capacity of free memory in KB
%3 = Type of memory, "D" =non-battery-backed, "S" =battery-backed
Definitions:
The alarm can only occur after a 'cold start' (=NCK start-up with standard machine data). The alarm
is only a notice. There is no interference with any NCK functions. It shows that the NCK has less free
user memory available than specified by Siemens for this control variant. The value of the actually
available free user memory can also be taken from the machine data
$MN_INFO_FREE_MEM_DYNAMIC, $MN_INFO_FREE_MEM_STATIC. Siemens supplies NCK
with default settings that, depending on the model, have certain (free) memory space available for the
specific settings of the actual applications. The original factory setting of NCK systems is thus that the
alarm does not occur with a cold start.
Reaction:
Alarm display.
Remedy:
Reasons for the message:
- The NCK contains compile cycle software, that uses so much memory space that the hardware
cannot provide the required memory.
- The NCK runs on hardware that is not intended for this NCK release (i.e. that has not enough
memory capacity).
- If the application runs properly with the remaining free user memory (i.e. can be started up without
any errors), the message can simply be ignored.
- If the actual application cannot be configured because there is not enough memory capacity
available, either the existing compile cycle must be reduced or, if possible, the system must be
upgraded with additional memory space.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
6100
Error while creating %1, error number %2 %3
Parameters:
%1 = Symbolname
%2 = Error code
%3 = If required, internal error identifier
Definitions:
An error was detected while creating a compile cycle machine data. The error number specifies the
type of error.
- Error number 1: Insufficient memory available
- Error number 2: Symbol in the NCK already exists
- Error number 3: Maximum possible number of symbols exceeded
- Error number 4: Invalid name prefix
- Error number 5: Illegal array size
Note: Other errors of this type could have occurred, but have not been displayed.
Reaction:
NC not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
- Error number 1: The memory reserved by machine data 12328 $MN_MM_CC_MD_MEM_SIZE has
to be increased. If the error occurs while loading an archive, then the machine data must be increased
"manually". To do this, either Edit the archive with 'arcedit' or Overwrite the MD in the MD picture and
prevent the deletion of the machine data when writing the archive (MMC: Set
Ask_for_CFG_RESET.INI = 1 in 'dino.ini'). Also refer to: Upgrade instructions P6.x.
- Error number 2: Error in the combination or while reloading compile cycles: Do not activate compile
cycle.
- Error number 3: Error in the combination or while reloading compile cycles: Do not activate compile
cycle.
- Error number 4: Error in the compile cycle: Do not activate compile cycle.
- Error number 5: Error in the compile cycle: Do not activate compile cycle.
Program
Switch control OFF - ON.
Continuation:
2-68
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
11/2006

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents