The selection is not possible. The file %1 has insufficient read rights.
Parameters:
%1 = Program name with path
Definitions:
The file has insufficient read rights for the current access level.
Reaction:
Alarm display.
Remedy:
Set the required read rights by means of keyswitch or password entry.
The alarm disappears automatically as soon as a program is edited or simulated in the program area.
The alarm can also be acknowledged manually via diagnostics.
Program
Internal
Continuation:
120305
Selection is not possible. The file %1 is currently being edited.
Parameters:
%1 = Program name with path
Definitions:
The file is currently open in another application (e.g. services) with an editor.
Reaction:
Alarm display.
Remedy:
Change the program in the already open editor.
The alarm disappears automatically as soon as a program is edited or simulated in the program area.
The alarm can also be acknowledged manually via diagnostics.
Program
Internal
Continuation:
120306
The selection is not possible. The file %1 is selected and active in
channel %2.
Parameters:
%1 = Program name with path
%2 = Channel number
Definitions:
--
Reaction:
Alarm display.
Remedy:
Stop the program with the NCU's channel reset and make the selection again.
The alarm disappears automatically as soon as a program is edited or simulated in the program area.
The alarm can also be acknowledged manually via diagnostics.
Program
Internal
Continuation:
120307
The file %1 cannot be opened for the editor because it is selected in
channel %2 for execution from external sources.
Parameters:
%1 = Program name with path
%2 = Channel number
Definitions:
--
Reaction:
Alarm display.
Remedy:
A different program on the NCU or for execution from external sources has to be selected.
The alarm disappears automatically as soon as a program is edited or simulated in the program area.
The alarm can also be acknowledged manually via diagnostics.
Program
Internal
Continuation:
120308
In the event of an emergency stop, the program %1 can only be changed
in the machine/program correction area.
Parameters:
%1 = Program name with path
Definitions:
--
Reaction:
Alarm display.
Remedy:
Switch to the machine area and change the program with the program correction function.
The alarm disappears automatically as soon as a program is edited or simulated in the program area.
The alarm can also be acknowledged manually via diagnostics.
Program
Internal
Continuation:
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
Overview of Alarms
HMI alarms
2-679

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents