Siemens SINUMERIK 840Di Diagnostic Manual page 514

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

Overview of Alarms
NCK alarms
61200
Channel %1 block %2: Too many elements in machining block
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The machining block contains too many elements.
Alarm triggered by following cycles: CYCLE76, CYCLE77, E_CALL, E_DR, E_DR_BGF, E_DR_BOR,
E_DR_O1, E_DR_PEC, E_DR_REA, E_DR_SIN, E_DR_TAP, E_MI_TR, E_PI_CIR, E_PI_REC,
E_PO_CIR, E_PO_REC, E_PS_CIR, E_PS_FRA, E_PS_HIN, E_PS_MRX, E_PS_POL,
E_PS_ROW, E_PS_SEQ, E_PS_XYA, E_SL_LON, F_DR, F_DR_PEC, F_DR_REA, F_DR_SIN,
F_DR_TAP, F_MI_TR, F_PI_CIR, F_PI_REC, F_PO_CIR, F_PO_REC, F_PS_CIR, F_PS_MRX,
F_PS_ROW, F_PS_SEQ, F_SL_LON
Remedy:
Check the machining block, delete some elements, if required.
61201
Channel %1 block %2: Wrong sequence in machining block
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The sequence of elements in the machining block is invalid.
Alarm triggered by following cycles: E_CP_CE, E_CP_DR, E_MANAGE, F_CP_CE, F_CP_DR,
F_MANAGE.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Sort the sequence in the machining block.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61202
Channel %1 block %2: No technology cycle
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
No technology cycle was programmed in the machining block.
Alarm triggered by following cycles: E_MANAGE, F_MANAGE.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program a technology block.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61203
Channel %1 block %2: No position cycle
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
No positioning cycle was programmed in the machining block.
Alarm triggered by following cycles: E_MANAGE, F_MANAGE.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program positioning block.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
2-514
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition