Siemens SINUMERIK 840Di Diagnostic Manual page 662

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

Overview of Alarms
HMI alarms
112200
The contour is a step in the current program%nsequence. Machining not
enabled
Definitions:
The contour is an element from a loaded program and cannot be deleted or renamed.
Reaction:
Alarm display.
Remedy:
Remove the contour from the loaded program.
Program
Internal
Continuation:
112201
Contour is step in current automatic chain%nMachining not possible.
Definitions:
The contour is an element of a program loaded under "Machine auto" and cannot be deleted or
renamed.
After the program has been started, the integrated contours cannot be changed under "Program"
while the program is running.
Reaction:
Alarm display.
Remedy:
Stop the program and load it under "Program". Remove the contour from the program.
Program
Internal
Continuation:
112210
Tool axis cannot be changed. Not enough NC-%nmemory.
Definitions:
If the tool axis is reselected, the NC program has to be generated again. Hereby the old NC program
is saved first.
Then the new program is generated. Here, the NC memory is insufficient to save the new program.
The reselection of the tool axis was not carried out.
Reaction:
Alarm display.
Remedy:
Free memory space must be created on the NC, and it must be enough for the program to be
processed (e.g. by deleting programs that are no longer required).
Program
Internal
Continuation:
112211
Tool preselection cannot be processed.%nNot enough NC memory.
Definitions:
When tool preselection is processed, the NC program has to be generated again. Hereby the old NC
program is saved first.
Then the new program is generated. Here, the NC memory is insufficient to save the new program.
The tool preselection is not processed.
Reaction:
Alarm display.
Remedy:
Free memory space must be created on the NC, and it must be enough for the program to be
processed (e.g. by deleting programs that are no longer required).
Program
Internal
Continuation:
112300
Tool management concept 2 not possible%nMagazine not completely
loaded.
Definitions:
The magazine is not completely loaded with tools.
In the magazine of tool management type 2, the number of tools specified in machine data 18082 has
to be created.
Reaction:
Alarm display.
Remedy:
Installation and start-up: Create the correct number of tools.
Program
Internal
Continuation:
2-662
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
11/2006

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents