Siemens SINUMERIK 840Di Diagnostic Manual page 523

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

11/2006
61241
Channel %1 Block %2: Retraction plane not defined for this machining
direction
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
No retraction plane has been defined for the selected machining direction.
Alarm triggered by following cycles: F_SP_RP, F_SP_RPT.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Define the missing retraction plane.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61242
Channel %1 block %2: Wrong machine direction
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The machining direction has been specified incorrectly.
Alarm triggered by following cycles: F_DR, F_DR_PEC, F_DR_REA, F_DR_SIN, F_DR_TAP,
F_DRILL, F_DRILLC, F_DRILLD, F_DRM_DR, F_DRM_PE, F_DRM_RE, F_DRM_SI, F_DRM_TA,
F_MI_CON, F_MI_EDG, F_MI_TR, F_MI_TXT, F_MIM_TR, F_PI_CIR, F_PI_REC, F_PO_CIR,
F_PO_REC, F_SL_CIR, F_SL_LON, F_TAP.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Check the programmed machining direction.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61243
Channel %1 block %2: Correct tool change point, tool tip in
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The tool change point must be situated so far outside the retraction area that no tool protrudes into
the retraction area on turret swivelling.
Alarm triggered by following cycle: F_SP_RP
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Specify another tool change point.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61244
Channel %1 block %2: Pitch change causing
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The specified lead change causes a reversal of the thread direction.
Alarm triggered by following cycle: CYCLE99
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Check lead change and thread geometry.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
Overview of Alarms
NCK alarms
2-523

Hide quick links:

Advertisement

Table of Contents
loading