14033
Channel %1 block %2 involute: no end point programmed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
No end point was programmed for the involute. This is either possible via direct programming with the
geometry axis identifiers or by specifying the angle between start and end vector.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14034
Channel %1 block %2 involute: angle of rotation too large
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
With programming of the angle of rotation (with AR) for involute interpolation, the maximum
programmable angle of rotation is limited if the involute is moving towards the basic circle. The
maximum value is reached if the involute touches the basic circle. With
MD_INVOLUTE_AUTO_ANGLE_RESTRICTION = TRUE, each angle is accepted without an alarm;
if necessary, the angle is automatically limited during interpolation.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14035
Channel %1 block %2 involute: start point invalid
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
With involute interpolation, the start point of the involute must be outside the basic circle. The
programmed center point or radius must be adapted accordingly.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14036
Channel %1 block %2 involute: end point invalid
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
With involute interpolation, the end point of the involute must be outside the basic circle. The
programmed center point / radius or end point must be adapted accordingly.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation: