Siemens SINUMERIK 840Di Diagnostic Manual page 849

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

11/2006
No. 98
Explanation
Extended stop and retract
Cause
-
Remedy
-
No. 99
Explanation
Block search (general) is currently being activated (negative acknowledgement may be
output for PI service).
Cause
-
Remedy
-
No. 100
Explanation
Integrated block search, i.e., a block search is restarted on a stopped program.
Cause
-
Remedy
-
No. 101
Explanation
External zero offset is activated via the PLC. Movement is stopped, a Reorg is per-
formed, the interpreter is switched over and then selected using REPOS and continued
automatically.
Cause
1. The channel is not in AUTO or MDA
2. The channel is stopped and the current block cannot be reorganized.
− Select Auto or MDI
Remedy
− Activate a block change until the NC block can be reorganized.
No. 102
Explanation
Single block type 3 is activated. With single block type 3, a stop is performed at all main
blocks. Unlike single block type 1, the part program command SBLOF is ignored.
Cause
-
Remedy
-
No. 103
Explanation
Stopping of a single axis movement (VDI signal)
Cause
The axis is not controlled by the PLC. (exception old reaction with oscillation axis).
Remedy
-
© Siemens AG, 2006. All rights reserved