Overview of Alarms
HMI alarms
120309
The selection is not possible. Please close the simulation and repeat the
selection.
Definitions:
The simulation is currently active in the program area.
A simultaneous editing is not possible.
Reaction:
Alarm display.
Remedy:
Close the simulation and make the selection again.
The alarm disappears automatically as soon as a program is edited or simulated in the program area.
The alarm can also be acknowledged manually via diagnostics.
Program
Internal
Continuation:
120310
The selection is not possible. Please wait for the pending action or
terminate it, then repeat the selection.
Definitions:
In the program area, programs are currently being copied, loaded or unloaded.
A simultaneous editing is not possible.
Reaction:
Alarm display.
Remedy:
Wait until the action is completed or terminate the action via the softkey "Cancel" and then repeat the
selection.
The alarm disappears automatically as soon as a program is edited or simulated in the program area.
The alarm can also be acknowledged manually via diagnostics.
Program
Internal
Continuation:
129900
Data of passive drives are not backed up!
Definitions:
This indicates that passive drives are not backed up as well when an upgrade is made.
Reaction:
Alarm display.
Remedy:
If the drive shall be backed up as well, it must be enabled. If the note shall not be displayed again, set
the drive to "0" in machine data 30240 ENC_TYPE and 30130 CTRLOUT_TYPE.
Program
Internal
Continuation:
129901
Time determination is being initialized. Please wait...
Definitions:
This indicates that the time determination is being initialized and that the operator shall not yet press
NC Start or execute other operator actions.
Reaction:
Alarm display.
Remedy:
Not necessary. After completion of the initialization, the dialog box will be faded out again
automatically.
Program
Internal
Continuation:
129902
Recorded data are being processed. Please wait...
Definitions:
This indicates that data recorded by time determination are currently processed and that the operator
shall not yet press NC Start or execute other operating actions.
Reaction:
Alarm display.
Remedy:
Not necessary. After completion of the initialization, the dialog box will be faded out again
automatically.
Program
Internal
Continuation:
2-680
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition