Overview of Alarms
NCK alarms
14114
Channel %1 block %2 programmed tilt angle too large
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
No further explanation.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14115
Channel %1 block %2 illegal definition of workpiece surface
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The surface normal vectors programmed at the beginning of block and at the end of block point in
opposite directions.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14116
Channel %1 block %2 absolute orientation programmed while
ORIPATH/ORIPATHS is active
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The orientation has been entered as an absolute value (e.g. by a direction vector or a rotation vector),
although ORIPATH or ORIPATHS are active. When ORIPATH/ORIPATHS is active, the orientation is
determined from the lead angle, tilt angle and angle of rotation relative to the path tangent and surface
normal vector.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14117
Channel %1 block %2 no angle or direction of the cone programmmed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
With taper circumference interpolation of orientation (ORICONCW and ORICONCC), either the
opening angle or the direction vector of the taper must be programmed. Otherwise, the change of
orientation is not clearly defined.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
2-212